* Add Tuya Energy monitoring by Shantur Rathore
* Add phase 1 Domoticz P1 Smart Meter support using energy sensors handled by xdrv_03_energy.ino based on an idea by pablozg
* Add commands Tariff1 0..23 (start Off-Peak hour), Tariff2 0..23 (start Standard hour) and Tariff3 0/1 (Saturday and Sunday Off-Peak)
6.5.0.16 20190611
* Refactored TLS based on BearSSL, warning breaking change for fingerprints validation (see doc)
* Add checkbox to GUI password field enabling visibility during password entry only (#5934)
6.5.0.14 20190602
* Change webserver HTML input, button, textarea, and select name based on id
* Fix webserver multiple Javascript window.onload functionality
6.5.0.12 20190521
* Add AriLux RF control GPIO option "ALux IrSel" (159) replacing "Led4i" (59) for full LED control (#5709)
* Add LED GPIO option "LedLink" (157) and "LedLinki" (158) to select dedicated link status LED (#5709)
* Add support for up to four LEDs related to four power outputs. Enabled when "LedLink(i)" is configured too (#5709)
* Add extended LED power control using command LedPowerX where X is 1 to 4. Enabled when "LedLink(i)" is configured too (#5709)
6.5.0.11 20190517
* Add command SetOption64 0/1 to switch between "-" or "_" as sensor index separator impacting DS18X20, DHT, BMP and SHT3X sensor names (#5689)
6.5.0.11 20190517
* Add user define INDEX_SEPARATOR to control Sensor Name index character which was fixed to "-" (minus) but is now changed to "_" (underscore) for future support.
* This change impacts DS18X20, DHT, BMP and SHT3X sensor names.
6.5.0.10 20190513
* Enable ADC0 by default in my_user_config.h (#5671)
* Add user configurable ADC0 to Module and Template configuration compatible with current FLAG options (#5671)
6.5.0.6 20190409
* Add WebColor parameters to Settings making them persistent and remove the need for using a rule
* Add alternative IRSend command syntax IRSend raw,<freq>,<header mark>,<header space>,<bit mark>,<zero space>,<one space>,<bit stream> (#5610)
6.4.1.14 20190203
* Add SetOption32 until SetOption49 diagnostic information to Status 3 report as replacement for second property value in SetOption property name
* Add Resolution property to Status 3 report providing previous SetOption second value property
6.4.1.11 20190124
* Remove command SetOption14 as it has been superseded by command Interlock
* Remove command SetOption63 as it has been superseded by command Interlock
* Add command Interlock 0 / 1 / 1,2 3,4 .. to control interlock ON/OFF and add up to 8 relays in 1 to 4 interlock groups (#5014)
6.4.1.8 20190107
* Change sonoff_template.h layout regarding optional module flags like ADC0
* Add command SetOption62 1 to force no Button/Switch pullup on dedicated modules. Currently only supported on Shelly2 (#4841)