Capable Tuya serial devices send power metering data over serial interface. User needs to identify the ids of all power metering functions and set as
SetOption44 -> Voltage
SetOption45 -> Current
SetOption46 -> Power
New Tuya Dimmer has dim values from 0 to 24. Currently the code expects it to be 0-100 or 0-255.
With this change we move the flag to a param and use that to calculate correct dim percentage.
This change also makes sure to update settings on version upgrade.
Tuya switches are detected as dimmers even after setting SetOption65 to 1.
Currently SetOption65 just hides the dimmer from Web UI for Tuya switches with SetOption65 to 1 but they are advertised as dimmer to HASS.
With this change we set light_type to LT_BASIC (on/off) instead of LT_SERIAL1 (dimmable) when option 65 is set.
* Refactor energy commands
* Add define USE_ENERGY_MARGIN_DETECTION to disable Energy Margin and Power Limit detection
* Add define USE_ENERGY_POWER_LIMIT to disable Energy Power Limit detection while Energy Margin detection is active