# LoRaWAN Decoder file for Dragino LHT52
#
# References
# User Manual: https://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT52%20-%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20User%20Manual/
# TTN Device Repository: https://github.com/TheThingsNetwork/lorawan-devices/blob/master/vendor/dragino/lht52.js
import string
if !global.lht52Nodes # data survive to decoder reload
global.lht52Nodes = {}
end
class LwDecoLHT52
static def decodeUplink(Name, Node, RSSI, FPort, Bytes)
var data = {"Device":"Dragino LHT52"}
var valid_values = false
var last_seen = 1451602800
var battery_last_seen = 1451602800
var battery = 1000
var rssi = RSSI
var temp_int = 1000
var humidity
var temp_ext = 1000
if global.lht52Nodes.find(Node)
last_seen = global.lht52Nodes.item(Node)[2]
battery_last_seen = global.lht52Nodes.item(Node)[3]
battery = global.lht52Nodes.item(Node)[4]
rssi = global.lht52Nodes.item(Node)[5]
temp_int = global.lht52Nodes.item(Node)[6]
humidity = global.lht52Nodes.item(Node)[7]
temp_ext = global.lht52Nodes.item(Node)[8]
end
## SENSOR DATA ##
if 2 == FPort && Bytes.size() == 11
last_seen = tasmota.rtc('local')
var TempC
TempC = Bytes[0] << 8 | Bytes[1]
if Bytes[0] > 0x7F
TempC -= 0x10000
end
TempC /= 100.0
data.insert("TempC_Internal", TempC)
temp_int = TempC
TempC = Bytes[4] << 8 | Bytes[5]
if 0x7FFF == TempC
data.insert("Ext_SensorConnected", false)
else
data.insert("Ext_SensorConnected", true)
if Bytes[4] > 0x7F
TempC -= 0x10000
end
TempC /= 100.0
data.insert("TempC_External", TempC)
temp_ext = TempC
end
data.insert("Hum_Internal", ((Bytes[2] << 8) | Bytes[3]) / 10.0)
humidity = ((Bytes[2] << 8) | Bytes[3]) / 10.0
data.insert("Ext_SensorType", Bytes[6])
var epoch = (Bytes[7] << 24) | (Bytes[8] << 16) | (Bytes[9] << 8) | Bytes[10]
data.insert("Systimestamp",tasmota.time_str(epoch))
valid_values = true
## STATUS DATA ##
elif 5 == FPort && Bytes.size() == 7
data.insert("Sensor_Model",Bytes[0])
data.insert("Firmware_Version", f'v{Bytes[1]:%u}.{Bytes[2]>>4:%u}.{Bytes[2]&0xF:%u}')
data.insert("Freq_Band",LwRegions[Bytes[3]-1])
data.insert("Sub_Band",Bytes[4])
data.insert("BattV",((Bytes[5] << 8) | Bytes[6]) / 1000.0)
battery_last_seen = tasmota.rtc('local')
battery = ((Bytes[5] << 8) | Bytes[6]) / 1000.0
valid_values = true
else
# Ignore other Fports
end #Fport
if valid_values
if global.lht52Nodes.find(Node)
global.lht52Nodes.remove(Node)
end
# sensor[0] [1] [2] [3] [4] [5] [6] [7] [8]
global.lht52Nodes.insert(Node, [Name, Node, last_seen, battery_last_seen, battery, RSSI, temp_int, humidity, temp_ext])
end
return data
end #decodeUplink()
static def add_web_sensor()
var msg = ""
for sensor: global.lht52Nodes
var name = sensor[0]
if string.find(name, "LHT52") > -1 # If LoRaWanName contains LHT52 use LHT52-<node>
name = string.format("LHT52-%i", sensor[1])
end
var name_tooltip = "Dragino LHT52"
var last_seen = sensor[2]
var battery_last_seen = sensor[3]
var battery = sensor[4]
var rssi = sensor[5]
msg += lwdecode.header(name, name_tooltip, battery, battery_last_seen, rssi, last_seen)
# Sensors
var temp_int = sensor[6]
var humidity = sensor[7]
var temp_ext = sensor[8]
msg += "<tr class='htr'><td colspan='4'>&#9478;" # |
if temp_int < 1000
msg += string.format(" &#x2600;&#xFE0F; %.1f°C", temp_int) # Sunshine - Temperature internal
msg += string.format(" &#x1F4A7; %.1f%%", humidity) # Raindrop - Humidity
end
if temp_ext < 1000
msg += string.format(" &#x2600;&#xFE0F; ext %.1f°C", temp_ext) # Sunshine - Temperature external
end
msg += "{e}" # = </td></tr>
end
return msg
end #add_web_sensor()
end #class
LwDeco = LwDecoLHT52