I observed that the definition of command names became mangled with commit 2bc5f682b0 due to vertical bar not being placed where it should. With no bar after `D_CMND_CPU_FREQUENCY`, the command name became concatenated with the next `D_CMND_SETSENSOR` with the "funny" effect that command name `CpuFrequencySetSensor` got matched with `&CmndSetSensor`
The reason for it not being matched with `&CmndCpuFrequency` is that there is a bar too many before the `Info` command name, as previous command name lines all finish with `"|"`. Hence an extra command table entry was created, meaning that the mismatch "only" affected command names `Info`, `TouchCal`, `TouchThres`, `CpuFrequency` and `SetSensor`.
Issue is only for ESP32, as both mishaps happened in a block conditional on `#ifdef ESP32`.
Arguably, it could make sense to have all the lines with command names start with `"|"` as a consistent way of formatting the lines without the special case of ending `"|"` to be omitted for the very last command name line, but I wanted to only make minimal changes