Improve rule enabling reliability
- Add 0.5s delay before enabling rule to let device process rule content - Use retry logic for rule enable command (3 attempts with 1s delay) - Change failed enable from warning to error and fail the command - Ensures rules are both set AND enabled for switches to work
This commit is contained in:
parent
70e0b038e6
commit
12ebdbf3e9
@ -207,6 +207,9 @@ class ConsoleSettingsManager:
|
||||
if param_name.lower().startswith('rule'):
|
||||
rule_number = param_name.lower().replace('rule', '')
|
||||
if rule_number.isdigit():
|
||||
# Wait for device to process the rule before enabling
|
||||
time.sleep(0.5)
|
||||
|
||||
# Use Rule{N} 4 to enable without setting Once flag
|
||||
# Rule 1 = Enable + Once ON (WRONG - causes single-fire issue)
|
||||
# Rule 4 = Enable only (CORRECT - allows repeated firing)
|
||||
@ -214,12 +217,17 @@ class ConsoleSettingsManager:
|
||||
|
||||
self.logger.debug(f"{device_name}: Enabling rule{rule_number} (Once=OFF)")
|
||||
|
||||
result, success = send_tasmota_command(
|
||||
device_ip, enable_command, timeout=5, logger=self.logger
|
||||
result, success = retry_command(
|
||||
lambda: send_tasmota_command(device_ip, enable_command, timeout=5, logger=self.logger),
|
||||
max_attempts=3,
|
||||
delay=1.0,
|
||||
logger=self.logger,
|
||||
device_name=device_name
|
||||
)
|
||||
|
||||
if not success:
|
||||
self.logger.warning(f"{device_name}: Failed to enable rule{rule_number}")
|
||||
self.logger.error(f"{device_name}: Failed to enable rule{rule_number} after 3 attempts")
|
||||
return False
|
||||
|
||||
time.sleep(0.3) # Brief delay between commands
|
||||
return True
|
||||
|
||||