# FullTopic Parameter Fix Summary
## Issue Description
When setting the MQTT parameters for FullTopic, the Full Topic was ending up with a %20 at the beginning, as in "%20%prefix%/%topic%/" instead of the correct "%prefix%/%topic%/".
## Root Cause
The issue was in the URL construction when sending commands to Tasmota devices. The code was using a space (%20 in URL encoding) between the command name and its value for all parameters:
```python
url = f"http://{ip}/cm?cmnd={setting}%20{value}"
```
While this works for most parameters, it causes problems with the FullTopic parameter because the space gets included in the value.
## Fix Implemented
The fix adds special handling for the FullTopic parameter by using "=" instead of a space (%20) between the command and value:
```python
# For FullTopic, we need to avoid adding a space (%20) between the command and value
if setting == "FullTopic":
url = f"http://{ip}/cm?cmnd={setting}={value}"
else:
url = f"http://{ip}/cm?cmnd={setting}%20{value}"
```
This change was implemented in two places:
1. In the `configure_unknown_device` method (around line 542)
2. In the MQTT settings update code (around line 937)
## Testing
A test script `test_fulltopic_fix.py` was created to verify the fix. The script:
1. Connects to a Tasmota device
2. Sets the FullTopic parameter using the new method
3. Verifies that the FullTopic is set correctly without the %20 prefix
To run the test:
```
./test_fulltopic_fix.py <ip_address>
```
Where `<ip_address>` is the IP address of a Tasmota device to test with.
## Expected Result
After this fix, the FullTopic parameter should be set correctly as "%prefix%/%topic%/" without the unwanted %20 at the beginning.