FullTopic Parameter Fix Summary

Issue Description

When setting the MQTT parameters for FullTopic, the Full Topic was ending up with a %20 at the beginning, as in "%20%prefix%/%topic%/" instead of the correct "%prefix%/%topic%/".

Root Cause

The issue was in the URL construction when sending commands to Tasmota devices. The code was using a space (%20 in URL encoding) between the command name and its value for all parameters:

url = f"http://{ip}/cm?cmnd={setting}%20{value}"

While this works for most parameters, it causes problems with the FullTopic parameter because the space gets included in the value.

Fix Implemented

The fix adds special handling for the FullTopic parameter by using "=" instead of a space (%20) between the command and value:

# For FullTopic, we need to avoid adding a space (%20) between the command and value
if setting == "FullTopic":
    url = f"http://{ip}/cm?cmnd={setting}={value}"
else:
    url = f"http://{ip}/cm?cmnd={setting}%20{value}"

This change was implemented in two places:

  1. In the configure_unknown_device method (around line 542)
  2. In the MQTT settings update code (around line 937)

Testing

A test script test_fulltopic_fix.py was created to verify the fix. The script:

  1. Connects to a Tasmota device
  2. Sets the FullTopic parameter using the new method
  3. Verifies that the FullTopic is set correctly without the %20 prefix

To run the test:

./test_fulltopic_fix.py <ip_address>

Where <ip_address> is the IP address of a Tasmota device to test with.

Expected Result

After this fix, the FullTopic parameter should be set correctly as "%prefix%/%topic%/" without the unwanted %20 at the beginning.